HOME > Á¦Ç°¼Ò°³ > STORAGE |
|
|
|
|
|
|
|
|
|
|
|
|
- ÃÖ»óÀÇ ¼º´É°ú Á¢¼Ó¼ºÀ» Á¦°øÇÏ´Â 4Gb Fibre channelÀÇ ÀåÁ¡ °ú Àú·ÅÇÑ S-ATA II ¿Í °í¼º´ÉÀÇ
SAS µ¿½Ã »ç¿ëÀ¸·Î À¯¿¬¼º°ú ³ôÀº È®Àå´É·Â Á¦°ø |
|
|
- Host Interface
* Single ¶Ç´Â Dual SAS Controller: Controller´ç 2°³ÀÇ SAS Port Á¦°ø, port´ç
1,200MB/secÀÇ Àü¼Û¼Óµµ Á¦°ø
* Controller´ç USB(RS232) port, Ethernet port, SAS Expansion port
Á¦°ø
-. Disk drive Interface
* °¢ port´ç 1,200MB/secÀÇ Àü¼Û¼Óµµ¸¦ Áö¿øÇÏ´Â SAS ±â¼ú Àû¿ë |
|
|
- Capacity: 146GB, 300GB, 450GB(SAS) & 500GB ,750GB, 1TB(S-ATA II) Áö¿ø
- Rotational velocity: 7,200rpm S-ATAII/SAS & 10,000~15,000rpm SAS
- Interface: 3Gb/sec S-ATAII & SAS
- Form factor: 3.5-inch form factor, 1.0-inch heigh |
|
|
- Processor: Intel Xscale 800MHz RISC Processor
- Hardware XOR
- Cache Memory: Controller´ç ÃÖ´ë 1GB, ½Ã½ºÅÛ´ç ÃÖ´ë 2GB
- ECC Memory Áö¿ø |
|
|
|
RAID ControllerÀÇ ±â´É ¹× Ư¡ |
|
|
- Dual active with automatic, transparent failover/ failback
- Auto-negotiate speeds
- In-band, Remote and out-of-band Web management
- Replacement controller reflashes FW to match peer controller
- Selective LUN deletion
- Battery Backup Unit Áö¿ø
- Write through, write back, or read-ahead cache support per logical
drive
- Variable cache line size and stripe size Per LUN
- Automatic Bad Sector Assignment
- Dedicated controller-to-controller communication path
- Background disk scrubbing and data integrity checking
- Concurrent RAID Level support - 0,1, 5, 6, 10, 50
- Each logical drive can have an independent RAID level
- On-line RAID Group expansion/partitioning
- Global hot spare drives assign a spare to a specified LUN
- Write through/back configurability per LUN |
|
|
- ´ÜÀÏ Enclosure´ç(2U) ÃÖ´ë 12°³ÀÇ µð½ºÅ© µå¶óÀ̺ê žÀç, ÃÖ´ë 60°³±îÁö È®Àå- È®Àå ¿ë·®: ÃÖ´ë
9TB ~ 60TB Áö¿ø |
|
|
|
Redundant & Hot-swappable components |
|
|
- RAID controllers & Disk & host I/O Card
- Power Supplies modules (APC)
- Disk drives |
|
|
- StorView GUI management: Windows, Solaris, Linux Áö¿ø
- Embedded StorView´Â Web base·Î OS¿¡ µ¶¸³ÀûÀ¸·Î ´Ù¾çÇÑ Áö¿ø
- Serial port management: OS¿¡ µ¶¸³Àû
- RAID Configuration Download & Upload Áö¿ø |
|
|
- Temperature, advanced power and cooling modules including fan
speed control, disk drives, and I/O module(s) |
|
|
- SCSI enclosure services (SES) over I2C physical interface, LEDs,
audible alarms
- FRU (field replaceable unit) revision and serial number reporting
- Events reported to StorVIew software |
|
|
- Input voltage: Autoranging, 110/220 VAC
- Input frequency: 50-60 Hz
- Input current: 100-240 VAC @5.0A
- Output power: Dual 300W Typical |
|
|
- CCC, BSMI, CE, UL, RoHS (R5), Microsoft WHQL, Microsoft RAID
System Submission - w/MPIO (Single Host) |
|
|
|
|
|
|
|
|
|
|